Please read and save these instructions. Read carefully before attempting to assemble, install, operate or
maintain the product described. Protect yourself and others by observing all safety information. Failure
to comply with instructions could result in personal injury and/or property damage! Retain
instructions for future reference.
1
The pedestal pump is designed for home
sump applications. The unit is equipped
with an 8-ft long, 3-prong grounding
type power cord. Motor is air cooled; it is
not designed to operate under water. A
float switch is provided for automatic
pump operation. This pump is not
suitable for aquatic life.
This manual contains information that
is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
Danger indicates
an imminently
hazardous situation which, if not
avoided, will result in death or serious
injury.
Warning indicates
a potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.
Caution indicates a
potentially
hazardous situation which, if not
avoided, may result in minor or
moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
1. Read these rules and
instructions carefully.
Failure to follow these
instructions could cause
serious bodily injury
and/or property
damage.
Operating Instruction and Parts Manual BTU30
360901-002 1/07
Do not submerge
motor or allow
motor to be exposed to water. Personal
injury and/or death could result.
Do not use to pump
flammable or explosive
fluids such as gasoline, fuel
oil, kerosene, etc. Do not
use in a flammable and/or explosive
atmosphere. Pump should only be used
to pump clear water. Personal injury
and/or death could result.
This pump is not
designed to handle
salt water, brine, laundry discharge or
any other application which may contain
caustic chemicals and/or foreign
materials. Pump damage could occur if
used in these applications and will void
warranty.
All wiring must be
performed by a
qualified electrician.
If the basement has water
or moisture on the floor, do
not walk on wet area until
all power is turned off. If the shutoff box
is in the basement, call an electrician.
Remove pump and either repair or
replace. Failure to follow this warning
could result in fatal electrical shock.
A battery backup
system should be
used. Call 1-888-636-6628 to order an
emergency backup system.
Always disconnect the
power source before
attempting to install,
service, relocate or maintain
the pump. Never touch sump pump,
pump motor, water or discharge piping
when pump is connected to electrical
power. Never handle a pump or pump
motor with wet hands or when standing
on wet or damp surface or in water. Fatal
electrical shock could occur.
1. Insert the float rod through hole in
the switch lever (See Figure 1).
2. Place rubber grommet on float rod
in temporary position.
3. Using pliers to hold the float rod,
screw the float on as shown in
Figure 1.
Pedestal
Sump Pump
Figure 1
Description
Safety Guidelines
General Safety
Information
Assembly
© 2007 Blue Angel™ Pumps
Seitenansicht 0
1 2 3 4 5 6 ... 11 12

Inhaltsverzeichnis

Seite 1 - Sump Pump

Please read and save these instructions. Read carefully before attempting to assemble, install, operate ormaintain the product described. Protect your

Seite 2 - Maintenance

Guía de Diagnóstico de AveríasProblema Posible(s) Causa(s) Acción a TomarLa bomba no seenciende nifuncionaLa bomba seenciende y seapagaconstantementeL

Seite 3 - Troubleshooting Chart

Limited WarrantyFor one year from date of purchase, Blue Angel (”Blue Angel“) will repair or replace, at its option, for the original purchaser anypar

Seite 4 - Replacement Parts List

NotesNotasGarantía LimitadaBlue Angel (”Blue Angel“) le ofrece una garantía de un año a partir de la fecha de compra, para reparar o reemplazar, según

Seite 5 - Pompe de Puisard

movement. Failure to secure pumpcould allow pump movement andswitch interference and prevent pumpfrom starting or stopping.IMPORTANT: Make sure there

Seite 6 - Entretien

3Troubleshooting ChartSymptom Possible Cause(s) Corrective ActionPump will not startor runPump starts andstops too oftenPump will not shutoff or therm

Seite 7 - Guide de Dépannage

4Please provide following information:- Model number- Serial number (if any)- Part description and number as shownin parts listAddress parts correspon

Seite 8 - Para Sumideros

5 FrS’il vous plaît lire et conserver ces instructions. Lire attentivement avant de monter, installer, utiliser oude procéder à l’entretien du produi

Seite 9 - Mantenimiento

6 FrInstructions d’Utilisation et Manuel de Pièces1. Un interrupteur contre undérangement dû à une miseaccidentelle à la terre (DDFT) estrequis.2. Cet

Seite 10

7 FrGuide de DépannageSymptôme Cause(s) Possible(s) Mesures CorrectivesLa pompe ne sedémarre pas et nefonctionne pasLa pompe se démarreet s’arrête tro

Seite 11 - Garantie Limitée

No sumerjael motor en el agua ni permita que estéexpuesto a ella. Puede ocasionarlesiones y/o muerte.No use esta unidad parabombear líquidos inflamab

Seite 12 - Garantía Limitada

9 Sp1. Se requiere un interruptor decircuito de pérdida a tierra. (GFCI)2. Esta bomba es para usarse con unsuministro de 120 V (monofásica),60 Hz y